Osiloscope NON

Rp84.007.440

In stock

BRAND : HANTEK

TYPE : 5102P

SPECIFICATIONS :

  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard (note: USB port is NOT intended to be used to recharge cell phones
  • & other usb charged devices. )
  • Multiple automatic measurements
  • Four math functions, including FFTs standard
  • Provides software for PC real-time analysis
  • Acquisition modes: normal, peak detect, average
  • Inputs coupling: AC, DC, GND
  • Inputs impedance: 1MΩ±2% ‖ 20pF±3pF
  • Probe attenuation: 1X, 10X
  • Supported Probe Attenuation Factor: 1X, 10X, 100X, 1000X
  • Maximum input voltage: CAT I and CAT II: 300VRMS (10×), Installation Category CAT III: 150VRMS (1×) Installation
  • Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal
  • waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration.
  • RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these
  • values are exceeded, damage to the oscilloscope may occur.
  • Sample rate range: 500MS/s–1GS/s
  • Waveform interpolation: (sin x)/x
  • Sample rate and delay time accuracy: ±50ppm(at over any ≥1ms time interval)
  • Position range: 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s
  • Rise time at BNC: 3.5ns
  • Math: +, -, *, /, FFT
  • FFT windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman, 1024 sample point
  • Bandwidth limit: 20MHz
  • Low frequency response: (-3db) >≤10Hz at BNC
  • DC gain accuracy: ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average
  • acquisition mode, 5mV/div to 2mV/div
  • DC measurement accuracy: When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only
  • 10mV/div or greater is selected. When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical
  • position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for
  • settings from 200mV/div to 5V/div
  • Trigger types: Edge, Video, Pulse, Slope, Over time, Alternative
  • Trigger source: CH1, CH2, EXT, EXT/5, AC Line
  • Trigger modes: Auto, Normal, Single
  • Coupling type: DC, AC, Noise Reject, HF Reject, LF Reject
  • Holdoff range: 100ns ~ 10s
  • Readout resolution: 6 digits
  • Accuracy (typical):±30ppm (including all frequency reference errors and ±1 count errors)
  • Frequency range: AC coupled, from 4Hz minimum to rated bandwidth
  • Output voltage: About 5Vpp into ≥1MΩ load
  • Size: 385mm x 200mm x 245mm
  • Weight: 2.08kg, 4.5 lbs
Compare
SKU: 5102P Categories: ,

BRAND : HANTEK

TYPE : 5102P

SPECIFICATIONS :

  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard (note: USB port is NOT intended to be used to recharge cell phones
  • & other usb charged devices. )
  • Multiple automatic measurements
  • Four math functions, including FFTs standard
  • Provides software for PC real-time analysis
  • Acquisition modes: normal, peak detect, average
  • Inputs coupling: AC, DC, GND
  • Inputs impedance: 1MΩ±2% ‖ 20pF±3pF
  • Probe attenuation: 1X, 10X
  • Supported Probe Attenuation Factor: 1X, 10X, 100X, 1000X
  • Maximum input voltage: CAT I and CAT II: 300VRMS (10×), Installation Category CAT III: 150VRMS (1×) Installation
  • Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal
  • waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration.
  • RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these
  • values are exceeded, damage to the oscilloscope may occur.
  • Sample rate range: 500MS/s–1GS/s
  • Waveform interpolation: (sin x)/x
  • Sample rate and delay time accuracy: ±50ppm(at over any ≥1ms time interval)
  • Position range: 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s
  • Rise time at BNC: 3.5ns
  • Math: +, -, *, /, FFT
  • FFT windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman, 1024 sample point
  • Bandwidth limit: 20MHz
  • Low frequency response: (-3db) >≤10Hz at BNC
  • DC gain accuracy: ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average
  • acquisition mode, 5mV/div to 2mV/div
  • DC measurement accuracy: When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only
  • 10mV/div or greater is selected. When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical
  • position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for
  • settings from 200mV/div to 5V/div
  • Trigger types: Edge, Video, Pulse, Slope, Over time, Alternative
  • Trigger source: CH1, CH2, EXT, EXT/5, AC Line
  • Trigger modes: Auto, Normal, Single
  • Coupling type: DC, AC, Noise Reject, HF Reject, LF Reject
  • Holdoff range: 100ns ~ 10s
  • Readout resolution: 6 digits
  • Accuracy (typical):±30ppm (including all frequency reference errors and ±1 count errors)
  • Frequency range: AC coupled, from 4Hz minimum to rated bandwidth
  • Output voltage: About 5Vpp into ≥1MΩ load
  • Size: 385mm x 200mm x 245mm
  • Weight: 2.08kg, 4.5 lbs
Be the first to review “Osiloscope NON”

Your email address will not be published. Required fields are marked *

seventeen + 9 =

Reviews

There are no reviews yet.

Main Menu

Osiloscope NON

Rp84.007.440

Add to Cart