Subtotal: Rp84.007.440
-
Osiloscope NON
BRAND : HANTEK
TYPE : 5102P
SPECIFICATIONS :
- Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
- USB host and device connectivity, standard (note: USB port is NOT intended to be used to recharge cell phones
- & other usb charged devices. )
- Multiple automatic measurements
- Four math functions, including FFTs standard
- Provides software for PC real-time analysis
- Acquisition modes: normal, peak detect, average
- Inputs coupling: AC, DC, GND
- Inputs impedance: 1MΩ±2% ‖ 20pF±3pF
- Probe attenuation: 1X, 10X
- Supported Probe Attenuation Factor: 1X, 10X, 100X, 1000X
- Maximum input voltage: CAT I and CAT II: 300VRMS (10×), Installation Category CAT III: 150VRMS (1×) Installation
- Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal
- waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration.
- RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these
- values are exceeded, damage to the oscilloscope may occur.
- Sample rate range: 500MS/s–1GS/s
- Waveform interpolation: (sin x)/x
- Sample rate and delay time accuracy: ±50ppm(at over any ≥1ms time interval)
- Position range: 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s
- Rise time at BNC: 3.5ns
- Math: +, -, *, /, FFT
- FFT windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman, 1024 sample point
- Bandwidth limit: 20MHz
- Low frequency response: (-3db) >≤10Hz at BNC
- DC gain accuracy: ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average
- acquisition mode, 5mV/div to 2mV/div
- DC measurement accuracy: When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only
- 10mV/div or greater is selected. When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical
- position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for
- settings from 200mV/div to 5V/div
- Trigger types: Edge, Video, Pulse, Slope, Over time, Alternative
- Trigger source: CH1, CH2, EXT, EXT/5, AC Line
- Trigger modes: Auto, Normal, Single
- Coupling type: DC, AC, Noise Reject, HF Reject, LF Reject
- Holdoff range: 100ns ~ 10s
- Readout resolution: 6 digits
- Accuracy (typical):±30ppm (including all frequency reference errors and ±1 count errors)
- Frequency range: AC coupled, from 4Hz minimum to rated bandwidth
- Output voltage: About 5Vpp into ≥1MΩ load
- Size: 385mm x 200mm x 245mm
- Weight: 2.08kg, 4.5 lbs
Rp84.007.440Osiloscope NON
Rp84.007.440